食品法规中心
法规中心
§129.20 瓶装饮用水的厂建设计(Plant construction and design)
2011-09-07 14:49  点击:3676
发布单位:FDA
发布文号:暂无
发布日期:暂无
生效日期:暂无
有效性状态:
废止日期:暂无
备注:条例规定瓶装室应以坚固墙壁、天花板和自动门与其他工厂操作和贮存区域分开以减少污染,在未封闭的条件下加工操作时需采取充分措施以排除水和系统的污染,对操作间、瓶装间和容器清洗消毒区域充分换气从而降低浓度,瓶子的清洗消毒在封闭室内进行将入瓶装室前受污染的可能性降到最低,水静置、处理的房间和容器、器具、设备清洗或静置的房间不能向其它任何内部房间直接开放。

      更多关于瓶装饮用水的相关法规,请详见美国FDA 21 CFR 第129部分关于瓶装饮用水生产和灌装的法规汇总

  § 129.20   Plant construction and design.

  (a) The bottling room shall be separated from other plant operations or storage areas by tight walls, ceilings, and self-closing doors to protect against contamination. Conveyor openings shall not exceed the size required to permit passage of containers.

  (b) If processing operations are conducted in other than a sealed system under pressure, adequate protection shall be provided to preclude contamination of the water and the system.

  (c) Adequate ventilation shall be provided to minimize condensation in processing rooms, bottling rooms, and in container washing and sanitizing areas.

  (d) The washing and sanitizing of containers for bottled drinking water shall be performed in an enclosed room. The washing and sanitizing operation shall be positioned within the room so as to minimize any possible post-sanitizing contamination of the containers before they enter the bottling room.

  (e) Rooms in which product water is handled, processed, or held or in which containers, utensils, or equipment are washed or held shall not open directly into any room used for domestic household purposes.

将全文内容保存为word文档
下一篇:§129.35 瓶装饮用水卫生设施(Sanitary facilities)
上一篇:§129.3 瓶装饮用水的相关定义(Definitions)
Baidu
map